| No. | Equipment Name | Description / Structure | Technical Parameters | Applications | Maintenance & Precautions |
|---|---|---|---|---|---|
| 1 | Straight Stream Nozzle
|
Used for extinguishing ordinary solid material fires and auxiliary cooling.
Non-shutoff type consists of coupling, barrel, and nozzle. Shutoff type includes valve; adjustable type includes spray ring for straight/ fog stream adjustment. |
Coupling diameter: 50mm, 65mm. Nozzle diameter: 13mm, 16mm, 19mm, 22mm. Rated pressure: 0.20MPa, 0.35MPa. Flow rate: 3.5–7.5L/s. Effective range: >20m. | Fire suppression and cooling operations. | Drain residual water after use, clean mud and stains, store in cool and dry place, inspect rotating parts regularly, lubricate and prevent rust. |
| 2 | Multi-function Fire Nozzle
|
Capable of producing straight stream, fog stream, water curtain, and other spray patterns; modes can be switched or combined. | Working pressure: 0.3–0.8MPa. Straight stream range: 36–42m. Flow rate: 2–8L/s. Spray angle: 90°–120°. | Versatile firefighting operations. | Drain water after use, clean thoroughly, store in cool and dry place, inspect moving parts, lubricate, avoid dropping or impact. |
| 3 | Foam Branch Pipe / Foam Nozzle
|
Consists of 1-barrel, 2-handwheel, 3-body, 4-ball valve, 5-suction tube, and 6-KY65 hose coupling. | Common models: PQ8, PQ16. Max working pressure: 0.8MPa. PQ8 flow: 8L/s, range ≥24m. PQ16 flow: 16L/s, range ≥28m. | Extinguishing flammable and combustible liquid fires; suitable for water-compatible solid fires. | Inspect regularly, keep clean and intact, flush thoroughly after use, check all connections for tightness. |
| 4 | Fire Hose
|
Used for transporting water and extinguishing agents at fire scenes. | Working pressure: 0.8MPa, 1.0MPa, 1.3MPa, 1.6MPa, 2.0MPa, 2.5MPa. Diameters: 40mm, 50mm, 65mm, 80mm, 90mm, 100mm, 125mm, 150mm, 300mm. Common sizes: 65mm, 80mm. | Water and foam delivery. | Operate within rated pressure, avoid twisting, sharp bends, sharp objects, chemicals, and heavy loads. Clean, dry, and store in cool dry place after use. |
| 5 | Fire Hose Accessories
|
Includes hose repair clamp, hose hook, and hose bridge. | — | Hose repair, suspension, and protection. | Keep clean and inspect for damage regularly. |
| 6 | Storz Coupling (Snap-type Coupling)
|
Used for connecting hoses, fire trucks, hydrants, and nozzles. | — | Quick hose connection. | Handle carefully, avoid deformation, inspect sealing spring and gasket, keep away from chemicals and heat sources. |
| 7 | Internal Lug Coupling
|
Used for connecting hoses, fire trucks, hydrants, and nozzles. | — | Hose system connections. | Handle carefully, inspect gaskets, avoid chemicals and heat exposure. |
| 8 | Reducing Coupling
|
Converts between different diameters such as 50mm, 65mm, 80mm. | — | Diameter conversion in hose systems. | Handle carefully, inspect gaskets, avoid chemicals and heat. |
| 9 | Adapter Coupling
|
Used to connect snap-type couplings and internal lug couplings. Composed of one internal lug coupling and one female snap coupling. | — | Coupling adaptation. | Handle carefully, inspect gaskets regularly, avoid chemicals and heat. |
| 10 | Water Distributor / Siamese Divider
|
Mainly composed of body, control valves, threaded couplings, and sealing rings. | — | Splitting one water source into multiple hose lines. | Check sealing rings and valve flexibility before use. Clean, dry, and lubricate after use. |
| 11 | Fire Suction Hose
|
Used by fire pumps or fire trucks to draft water from natural sources or outdoor hydrants. Composed of inner rubber layer, reinforcement layer, and outer rubber layer. | Diameters: 50mm, 65mm, 80mm, 90mm, 100mm, 125mm, 150mm. Common size: 100mm. Working pressure: 0.3MPa, 0.5MPa. Straight type lengths: 2m, 3m, 4m. Coil type lengths: 8m, 10m, 12m. | Water drafting. | Store in cool, dry, ventilated area. Avoid sunlight, rain, chemicals, and heat sources. Inspect regularly to prevent aging. |
| 12 | Suction Hose Accessories
|
Includes suction hose couplings, strainers, and suction hose wrenches. Strainers prevent debris from entering pumps; wrenches are typically made of carbon steel. | — | Suction system connection, filtration, and installation. | Keep clean, inspect regularly, prevent rust and damage. |
Conclusion
Water discharge and water supply equipment form the core of firefighting water delivery systems. From nozzles and foam branch pipes to hoses, couplings, distributors, and suction accessories, each component plays a vital role in ensuring efficient water transport, precise fire suppression, and reliable operational safety. Proper operation, routine inspection, cleaning, lubrication, and correct storage are essential to maintain equipment performance and extend service life during emergency firefighting operations.
Need more information for Fire Truck? Follow us at https://www.firerescuetruck.com/, if you have any inquiry about our Fire Truck, please send your RFQ to us, you will get the BEST price!